Cereal protein analysis via Dumas method: Standardization of a micro-method using the EuroVector Elemental Analyser

Thumbnail
View/Open
Embargado hasta 01/01/2100 (663.9Kb)
Author
Serrano, Salud
Rincón, Francisco
García-Olmo, J.
Publisher
Elsevier
Date
2013
Subject
Dumas method
Protein analysis
Kjeldahl method
Plackett–Burman experimental design
METS:
Mostrar el registro METS
PREMIS:
Mostrar el registro PREMIS
Metadata
Show full item record
Abstract
The Dumas method (DM) of protein analysis in foods was standardized using two cereal references in order to identify the main sources of error during analysis; specifically, the study sought to establish which of the apparent critical factors (ACFs) were really significant influencing factors (IF) for the application of the DM to protein analysis in cereals. Using a non-geometric Plackett-Burman experimental design augmented to resolution IV via fold-over by increasing to twenty-four runs, the following eleven ACFs were investigated: sample weight (WS), capsule sealing process (CW), carrier gas flow (PC), purge gas flow (FHe), oxygen volume (O2), oxygen pressure (ΔO2), sample delay time (SD), sample run time (SR), front furnace temperature (FFT), rear furnace temperature (RFT), and GC oven temperatures (GCT). Two IFs were identified for each of the factors RFT and GCT, so an optimization process was carried out, based on a central composite design. Optimized conditions, ensuring enhanced accuracy and repeatability when determining protein content in cereals using the DM, are reported.
Description
Embargado hasta 01/01/2100
URI
http://hdl.handle.net/10396/30110
Fuente
Serrano, S., Rincón, F., & García-Olmo, J. (2013). Cereal protein analysis via Dumas method: Standardization of a micro-method using the EuroVector Elemental Analyser. Journal Of Cereal Science, 58(1), 31-36. https://doi.org/10.1016/j.jcs.2013.04.006
Versión del Editor
https://doi.org/10.1016/j.jcs.2013.04.006
Collections
  • Artículos, capítulos, libros...UCO
  • DBTA-Artículos, capítulos, libros...

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
© Biblioteca Universidad de Córdoba
Biblioteca  UCODigital
 

 

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

Statistics

View Usage Statistics

De Interés

Archivo Delegado/AutoarchivoAyudaPolíticas de Helvia

Compartir


DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
© Biblioteca Universidad de Córdoba
Biblioteca  UCODigital