Show simple item record

dc.contributor.authorCaballero-Casero, Noelia
dc.contributor.authorRubio, Soledad
dc.date.accessioned2026-03-01T15:50:24Z
dc.date.available2026-03-01T15:50:24Z
dc.date.issued2021
dc.identifier.urihttp://hdl.handle.net/10396/35563
dc.description.abstractThe growing demand for a better understanding of the effects of chemical mixtures on human health has fostered the need for extensive estimation of uptake rates from identified sources and/or biomonitoring, which has encouraged the development of analyte- and matrix-independent analytical methods. In this paper, we report a comprehensive sample treatment platform for the efficient extraction and interference removal in the determination of twenty-one bisphenols and derivatives (log Kow from 1.254 to 6.564) in a variety of human exposure sources and biological fluids. Treatment of both liquid (canned beverages, urine and serum) and solid (canned food, dust) samples was based on the use of low volumes (190-200 µL) of a hexanol-based supramolecular solvent having properties of restricted access materials. The efficient extraction of bisphenol and derivatives (absolute recoveries 70-114%) was due to the mixed-mode mechanisms (hydrogen bonding, polar and dispersion interactions) and the huge number of binding sites offered by the supramolecular solvent with properties of restricted access materials for solute solubilization. Signal suppression or enhancement (SSE) values kept in the range 78-116% for samples encompassing a wide range of macromolecules content (e.g. protein, fat, carbohydrates, etc.). Quantification was carried out by liquid chromatography, electrospray tandem mass spectrometry using external calibration. Method quantitation limits for bisphenols in liquid and solid samples were in the interval 0.019-0.19 µg L-1 and 0.06-0.81 µg kg-1. The method was applied to the determination of bisphenols and derivatives in thirteen human exposure sources and biological fluids. Only four bisphenols out of twenty-one were not found in the analyzed samples. This supramolecular solvent-based bisphenol- and matrix-independent method constitutes a valuable strategy in terms of analytical and operational characteristics for the assessment of human exposure to mixtures of bisphenols and derivatives.es_ES
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/4.0/es_ES
dc.sourceAnalytica Chimica Acta 1144 (2021) 14e25es_ES
dc.subjectBisphenolses_ES
dc.subjectComprehensive sample treatmentes_ES
dc.subjectSupramolecular solventses_ES
dc.subjectBiomonitoringes_ES
dc.subjectMatrix-independent methodses_ES
dc.titleComprehensive supramolecular solvent-based sample treatment platform for evaluation of combined exposure to mixtures of bisphenols and derivatives by liquid chromatography-tandem mass spectrometryes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publisherversionhttps://doi.org/10.1016/j.aca.2020.11.057es_ES
dc.relation.projectIDeu-repo/grantAgreement/AEI/Programa Estatal de I+D+i Orientada a los Retos de la Sociedad/CTQ2017-83823-R/ESes_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record