Online removal of ocular artefacts from the electroencephalogram
Autor
Thomlinson, M.
López, J.M.L.
García, M.I.B.
Jervis, B.W.
Editor
Institution of Engineering and TechnologyFecha
2004Materia
EEG SignalsEOG
Electroencefalografía
Electrodiagnóstico
Biomicroscopía ocular
METS:
Mostrar el registro METSPREMIS:
Mostrar el registro PREMISMetadatos
Mostrar el registro completo del ítemResumen
A method by which ocular artefacts (OAs) in the electroencephalogram (EEG) may be removed automatically online by electro-oculogram (EOG) subtraction is demonstrated. This is achieved by a combination of recursively calculating the required cross-correlations, a fast matrix inversion method, and the use of a modem microprocessor with a high clock rate. Although recursive calculations are involved, the method itself is essentially non-recursive, which means that distortion of any evoked potentials is minimised. The method may be applied simultaneously to any number of EEG channels.