dc.contributor.authorCausse, Manuel
dc.contributor.authorRuiz, Pilar
dc.contributor.authorGutiérrez-Aroca, Juan-Bautista
dc.contributor.authorCasal Román, Manuel
dc.date.accessioned2018-12-19T09:11:53Z
dc.date.available2018-12-19T09:11:53Z
dc.date.issued2011
dc.identifier.urihttp://hdl.handle.net/10396/17593
dc.description.abstractApplication of real-time PCR for the detection of Mycobacterium tuberculosis enables results to be obtained in about 2 h. A total of 340 nonrespiratory samples were processed using two real-time PCR assay kits: Xpert MTB/RIF and Cobas TaqMan MTB. The sensitivity and specificity of the Xpert assay were 95% and 100%, respectively, compared to 78% and 98% for the Cobas assay.es_ES
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherAmerican Society for Microbilogyes_ES
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/4.0/es_ES
dc.sourceJournal of Clinical Microbiology 49 (8), 3065-3067 (2011)es_ES
dc.subjectM. tuberculosises_ES
dc.subjectReal-time PCRes_ES
dc.titleComparison of Two Molecular Methods for Rapid Diagnosis of Extrapulmonary Tuberculosises_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publisherversionhttps://doi.org/10.1128/JCM.00491-11es_ES
dc.relation.projectIDGobierno de España. REIPI RD06/0008es_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES