Mostrar el registro sencillo del ítem
Comparison of Two Molecular Methods for Rapid Diagnosis of Extrapulmonary Tuberculosis
dc.contributor.author | Causse, Manuel | |
dc.contributor.author | Ruiz, Pilar | |
dc.contributor.author | Gutiérrez-Aroca, Juan-Bautista | |
dc.contributor.author | Casal Román, Manuel | |
dc.date.accessioned | 2018-12-19T09:11:53Z | |
dc.date.available | 2018-12-19T09:11:53Z | |
dc.date.issued | 2011 | |
dc.identifier.uri | http://hdl.handle.net/10396/17593 | |
dc.description.abstract | Application of real-time PCR for the detection of Mycobacterium tuberculosis enables results to be obtained in about 2 h. A total of 340 nonrespiratory samples were processed using two real-time PCR assay kits: Xpert MTB/RIF and Cobas TaqMan MTB. The sensitivity and specificity of the Xpert assay were 95% and 100%, respectively, compared to 78% and 98% for the Cobas assay. | es_ES |
dc.format.mimetype | application/pdf | es_ES |
dc.language.iso | eng | es_ES |
dc.publisher | American Society for Microbilogy | es_ES |
dc.rights | https://creativecommons.org/licenses/by-nc-nd/4.0/ | es_ES |
dc.source | Journal of Clinical Microbiology 49 (8), 3065-3067 (2011) | es_ES |
dc.subject | M. tuberculosis | es_ES |
dc.subject | Real-time PCR | es_ES |
dc.title | Comparison of Two Molecular Methods for Rapid Diagnosis of Extrapulmonary Tuberculosis | es_ES |
dc.type | info:eu-repo/semantics/article | es_ES |
dc.relation.publisherversion | https://doi.org/10.1128/JCM.00491-11 | es_ES |
dc.relation.projectID | Gobierno de España. REIPI RD06/0008 | es_ES |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es_ES |